Actuator Selection Lesson 1: Multi-turn or Part-turn — One Table Explains It

source:    date:2026-11-18

In valve automation, the question we hear most often is not "how much torque" but: "Does this valve of mine need a multi-turn or a part-turn actuator?" It sounds basic, yet it is the first link in the selection chain — get this step wrong and all the torque calculation, bus configuration and trial commissioning that follow are wasted. One quick-reference table makes it clear, plus three common pitfalls and a three-step selection method.

1. First look at how the valve moves

An actuator is essentially the valve's "power arm"; the selection logic follows the valve's motion. There are only two types:

Multi-turn: the valve needs many revolutions to stroke — gate valves, globe valves and knife gate valves are the typical examples. The actuator outputs torque and turns the stem round by round until the valve reaches its position. Main feedwater valves in power stations, emergency shut-off valves on pipelines and large gate valves in waterworks all belong to this class.

Part-turn: the valve completes a full open-close cycle with 90° (or less) of rotation — ball valves, butterfly valves, plug valves and damper louvres. The actuator outputs torque plus a quarter-turn rotation. Fast isolation valves in wastewater plants and switching butterfly valves in chemical units are typical scenarios.

One-line rule: many turns — choose multi-turn; only 90° — choose part-turn. This is also the most fundamental dividing line between Rotork's IQ (multi-turn) and IQT (part-turn) ranges.

2. Three frequent pitfalls

Pitfall 1: forcing a multi-turn model onto a ball valve. Some projects, chasing "model uniformity", fit a multi-turn actuator to a 90° valve and make up the travel in turns. The result: a costlier device, one beat slower, and extra side thrust on the stem — a poor trade.

Pitfall 2: not separating on-off duty from modulating duty. Within part-turn, on-off service looks at stroking speed and torque margin, while modulating service looks at positioning accuracy and heating under frequent action. The IQ range has configurations for both — state the duty clearly in the specification instead of leaving just "motorized valve".

Pitfall 3: sizing torque on the calculated value alone. As valves age, deposits, scaling and packing tightening push the real operating torque well above the new-valve calculation. The industry norm is a generous safety factor, confirmed by measured torque during commissioning using the actuator's real-time torque monitoring (such as the independent torque sensing in the IQ range) — not by paper estimates alone.

3. One table aligning the two stroke types

Multi-turn vs part-turn quick reference:

DimensionMulti-turnPart-turn
Valve motionMultiple revolutions90° rotation
Matched valvesGate, globe, knife gateBall, butterfly, plug, dampers
Output requirementTorque + turnsTorque + rotation angle
Typical serviceFeedwater control, pipeline shut-off, large waterworks valvesFast switching, wastewater isolation, dampers
Rotork rangeIQ (incl. IQ3 / IQ3 Pro)IQT (incl. IQT3 / IQT3 Pro)

It is worth noting that IQ and IQT share the same intelligent platform: double-sealed enclosure, non-intrusive Bluetooth setup, position memory on power loss and SIL2/3 functional-safety certification are identical across both. Once the stroke type is fixed, the setup habits and maintenance experience carry over seamlessly — one reason many engineering companies standardize on the Rotork platform within a project.

4. A three-step selection method

Finally, today's essentials compressed into three steps you can pin above your desk:

Step 1, look at the valve stroke: many turns — multi-turn; 90° — part-turn. There is no ambiguity in this step;

Step 2, look at the duty: for on-off service watch stroking speed and torque margin; for modulating service watch positioning accuracy and action frequency;

Step 3, verify by measurement: during commissioning measure the operating torque with torque monitoring and confirm the margin — never let the paper calculation be the only basis.

Once the stroke type is settled, if you need pricing and supply for multi-turn or part-turn actuators, send us the valve parameters via our RFQ form.

Related reading

How to size an electric actuator: a nine-step workflow with the parameter checklist | Rotork IQ3 actuators: IQ3 Perform and IQ3 Pro | Rotork IQ series actuator wiring and commissioning | Rotork actuators: wiring, commissioning and 28 common faults (illustrated)

An industry resource for electric & pneumatic actuators, dampers and heaters: brand manuals, sizing guides and maintenance know-how. Global brands in, China manufacturing out.

Channels
Contact
  • Shandong Juxi Electromechanical Equipment Co.,Ltd.
  • Tel:+86-13853147838
  • WhatsApp: 13853147838 / 18678894019
  • LinkedIn: Shandong Juxi (Actuators.cn)
  • Email:actuators@163.com
© 2006-2026 China Electric Actuator Network How to contact us