Rotork IQ series electric actuators — Installation and Maintenance Manual (publication E170C2, March 2002, Chinese, 77 pages) for the world’s first actuator commissionable without opening the electrical covers: health & safety, storage, manual/electric operation, three valve mounting arrangements, primary and secondary setting, check routines, maintenance and troubleshooting, plus the infrared setter, diagnostics and the built-in data logger.
| Section | Contents (77-page manual) |
|---|---|
| 1–3 | Health & safety; storage; IQ operation (manual etc.) |
| 4 | Manual and electric (local/remote) operation; preparation and installation |
| 5 Installation | Rising-stem valves (top mount) / geared valves (side mount) / non-rising stem (top mount); handwheel sealing |
| 6–7 | Primary setting (per valve duty) and secondary setting (per control/indication needs); check routines; program branch (Cr); display setting/check; return to position indication |
| 8 Setting | Primary setting functions |
| Further | Maintenance & troubleshooting; sales and service |
| Setter | Infrared setter works with mains on or off — safe even in hazardous areas; a yellow label on the terminal box indicates whether a setter was supplied |
| Diagnostics & logging | Standard diagnostics watch control system, valve and actuator (icons + help screens); one key shows instantaneous torque at position; built-in data logger via IQ-Insight or the intrinsically safe communicator |